Configure and manage asset access after migrating from Access Control to Access Management

Learn how to correctly configure your devices and manage asset access after migrating from the legacy Access Control feature to Access Management.

If you have migrated from Access Control to Access Management, the way you lock and unlock assets has changed.

This article explains what has changed, how to configure your devices correctly, and how to troubleshoot common issues to prevent assets from becoming unintentionally locked or inaccessible.

Note: This guide applies to customers who have migrated from the legacy Access Control feature to Access Management.

For more content on Access Management, see here.

What changed?

The main difference is that asset access is now managed through Access Management in Trackunit Manager rather than manually through Output Mode in Verify

You will still need to use Verify to check that the migration has been set up correctly, but you will use Trackunit Manager and the Access Management app to lock/unlock assets.

Important configuration requirements

To ensure assets behave as expected after migrating to Access Management, there are three important configuration requirements to follow:

#

New Configuration Requirements

In Verify, IN2 --> OUT1 must always stay ON - this marks the device as migrated to Access Management. Do not turn it off.

*Relay Logic in Verify must match the physical relay mounting - NO (Normally Open) or NC (Normally Closed) on site must have the same settings in Verify.

Lock/unlock logic is set only in Trackunit Manager in the Access Mangement app. Never use Output Mode in Verify for locking and unlocking assets.

*Note: NC relay installations: with the old lock/unlock feature, OUT1 status matched the physical signal on the relay. That is no longer true. The Relay Logic setting in Verify now handles the translation to your physical wiring.

The sections below explain how to check and configure these settings.
​

Verify settings:

These three settings appear in Verify. Only two of them should be configured, and only once time at the time of installation of a device:

Three Verify Setting:

IN2 --> OUT1 -- Always on

Marks the device as onboarded to Access management. Never turn this off.

-----------------------------------------

Relay - Set once
Must match the physical relay on the asset. Normally Open (NO) pin 87, or Normally Closed (NC) pin 87a. A mismatch will block the asset.

-----------------------------------------

Output Mode - Do not use!
Output Mode no longer controls lock/unlock. Use Trackunit Manager instead.


By default, Output Mode will be toggled off, and should remain off.

Lock / Unlock via Trackunit Manager

Trackunit Manager is now the only place to control wether an asset can start or not.


From Trackunit Manager, go to the Access Management app, Find the asset under Assets, and click on it to open the Configuration bar:

Trackunit Manager Setting:

Meaning:

When to use:

Locked for all

Asset will not start for anyone

Asset should be immobilized

Unlocked for all

Asset can start for anyone

Open access on site

Unlocked for key

Start only after keypad or mobile unlock

Controlled access per operator

Locking an asset:

Trackunit Manager --> Access Management app --> Asset tab --> Select asset --> Configuration --> Select Unlocked for all or Unlocked for Key--> Save --> Always test on site.

Unlocking an asset:

Trackunit Manager --> Access Management app --> Asset tab --> Select asset --> Configuration --> Select Locked for all--> Save --> Always test on site.

The device reacts when a start is attempted. It is no longer an instant manual toggle via the Output Mode button in Verify.

Post-migration audit of assets

After migration, run this checklist on every asset which has already been migrated to Access Management:

#

Check

Expected

If wrong

1

Verify: IN2 --> OUT1

ON

Turn ON immediately

2

Verify: Relay Logic

Matches physical NO/NC

Correct the toggle to match relay on site

3

Verify: Output Mode

Not used for lock/unlock

Ignore, use Trackunit Manager instead

4

Trackunit Manager: Access Management configuration

Matches your intent

Select the desired locking mode (locked, unlocked, unlocked for key)

5

On-site test

Asset behavior matches Trackunit Manager settings

If the opposite is happening recheck the Relay Logic match (check #2)

Installation checklist for all new device installs

Step 1 - Physical Installation

Identify relay type on site: NO or NC

Wire the relay per Trackunit installation guide

Record relay type on the installation sheet

Step 2 - Verify Configuration

Find device in Verify.com

Confirm IN2 --> OUT1 is ON (it is on by default, just check, do not change it)

Ret Relay Logic to match physical relay (NO or NC)

Do not use Output Mode to lock/unlock

Save / apply setting

Step 3 - Access Management Configuration

Trackunit Manager --> Access Management app

Asset tab --> Click on Asset --> Configuration

Choose: Unlocked for all, Locked for all, or Unlocked for key

Save

Step 4 - On-Site Verification

Trackunit Manager --> Access Management app

Asset tab --> Click on Asset --> Configuration

Choose: Unlocked for all, Locked for all, or Unlocked for key

Save

Troubleshooting

Below are the most common issues that can arise if the new configuration is not followed:

Sympton

Likely cause

Fix

Avoid

Asset is blocked and won't start

Access Management configuration is set "Locked for all"

Change the Access Management configuration in Trackunit Manager

Avoid using Verify to Lock/Unlock

Asset blocked after migration

IN2 --> OUT1 is OFF

Go to Verify and set IN2 --> OUT1 to ON

Avoid turning IN2 --> OUT1 OFF

Opposite asset behavior observed

Relay Logic in Verify does not match physical relay

Go to Verify and toggle the correct Relay Logic (NO or NC)

Someone toggled Output Mode

Old lock/unlocking habbit

Use Trackunit Manager to lock/unlock assets.

Avoid using Output Mode in Verify to lock/unlock assets.

Mixed settings from different users

No single source of truth

Avoid using the old method for locking/unlocking assets.